EnSight Biportal
A complete solution for unilateral biportal endoscopic spine surgery (UBE): 4K endoscopic tower, Plasma and RF electrodes, dedicated instruments and an endoscopic drill.

NextAR Spine is Medacta’s augmented-reality application for spine surgery. The system measures the position of the instruments relative to the patient’s anatomy in real time and shows the information in the NextAR glasses, superimposed on the operative field, so the surgeon does not have to look away at a monitor.
Tracking uses compact, single-use active sensors mounted close to the treated levels, with no reflective markers and no bulky external camera in the room. The NextAR camera communicates with the control unit over Bluetooth, and the battery-powered NextAR target carries LEDs in a known configuration that the camera tracks.
The surgeon chooses between two workflows. In 3D-3D, implant placement is planned in advance on a 3D model built from a low-dose CT scan. In 3D DIRECT, the desired trajectories are saved intraoperatively with a single click. The same software and hardware cover open, mini-open and percutaneous approaches, and Medacta also uses the NextAR platform for the knee, hip and shoulder.

| Components | NextAR glasses, NextAR TS tracking system (camera and target), control unit, software |
|---|---|
| Camera to control unit link | Bluetooth |
| Sensors | Active, single-use; battery-powered LED target |
| Workflows | 3D-3D (planned on CT) and 3D DIRECT (intraoperative) |
| Planning imaging | Low-dose CT (3D-3D workflow) |
| Approach | Open, mini-open, percutaneous |
| Platform | NextAR, shared across spine, knee, hip and shoulder |



In the NextAR glasses. The angle, depth and trajectory of the instrument are superimposed on the operative field, so the surgeon does not look away at a monitor during the procedure.
No. Tracking uses compact, single-use active sensors mounted close to the operated levels: a small camera and a battery-powered LED target. The camera communicates with the control unit over Bluetooth, and no reflective markers are needed.
Two. In 3D-3D, implant placement is planned before surgery on a 3D model built from a low-dose CT scan. In 3D DIRECT, the surgeon saves the desired trajectories during surgery with a single click. Both cover open, mini-open and percutaneous approaches.
NextAR Spine is integrated with the MySpine planning tools of Medacta’s MySolutions ecosystem. The NextAR Rod Optimizer helps choose the right rod during surgery from a set of pre-bent rods, without manual bending.
Product
NextAR Spine
Medacta
Fill in the form and we will get back to you shortly, usually within the same working day.

A complete solution for unilateral biportal endoscopic spine surgery (UBE): 4K endoscopic tower, Plasma and RF electrodes, dedicated instruments and an endoscopic drill.

A complete sterile set for biportal and monoportal spinal endoscopy: drapes, camera cover, fluid collection and the small instruments needed, in a single pack.

A modular anterior cervical fusion (ACDF) system that combines a TiPEEK interbody cage with an anterior plate: 4 plate types, rigid or variable fixation, 8 configurations.