EnSight Biportal
A complete solution for unilateral biportal endoscopic spine surgery (UBE): 4K endoscopic tower, Plasma and RF electrodes, dedicated instruments and an endoscopic drill.


A single-use drill for minimally invasive harvesting of autologous cancellous bone: harvesting, transfer and collection in one step, through a 2-3 cm incision, in 2-3 minutes.
Autologous cancellous bone remains the reference standard for bone grafts, because it is osteogenic, osteoinductive and osteoconductive. Conventional harvesting, especially from the iliac crest, means a large incision, donor-site pain and extra operating time. XDrill harvests bone through an 8-10 mm bone window, and harvesting, transfer and collection of the graft are synchronised.
Harvesting is done at low speed and low temperature to preserve the activity of the osteogenic factors in the autograft, and depth-controlled sleeves give double protection. The same system harvests from the anterior and posterior iliac crest, proximal tibia, distal femur, calcaneus and distal radius. There are three steps: incision and exposure, site preparation and drilling, then graft harvesting.
The graft is used alone or mixed with other materials as needed: in spine surgery (ACDF, sacroiliac fusion, lateral XLIF, CLIF or OLIF fusion, atlantoaxial grafting), in post-traumatic nonunions and bone defects, in femoral head necrosis, in hand, foot and ankle surgery (cysts) and after curettage of bone tumours. According to the manufacturer, the donor-site defect heals in 3-6 months.

| Harvested amount | Anterior iliac crest 5-8 g, posterior 10-15 g (one side, adult); 7-15 cc per harvest, up to 30-50 cc when repeated, depending on donor-site bone volume |
|---|---|
| Harvest time | 2-3 minutes |
| Comparison presented by the manufacturer | XDrill versus conventional harvesting: incision 20-30 versus 50-80 mm; bone window 8-10 mm versus about 40 × 20 mm; operating time 2-3 versus 15-30 minutes; VAS pain at 2 weeks 0-1 versus 5-6 |
| Blood loss | 10-20 ml, according to the manufacturer |
| Registrations | CE, NMPA, ANVISA, TGA (CE class to be confirmed with the certificate) |
| Manufacturer | Zhejiang Furun Medical Technology Co., Ltd., Hangzhou, China |


From the anterior and posterior iliac crest, proximal tibia, distal femur, calcaneus and distal radius. On one side, in adults, the manufacturer gives 5-8 g from the anterior iliac crest and 10-15 g from the posterior crest.
2-3 minutes, through a 2-3 cm incision and an 8-10 mm bone window. Harvesting, transfer and collection of the graft happen in the same step.
Low speed and temperature preserve the activity of the osteogenic factors in the autograft, according to the manufacturer; autologous bone is valuable precisely because it is osteogenic, osteoinductive and osteoconductive.
Product
XDrill
Furun Medical
Fill in the form and we will get back to you shortly, usually within the same working day.

A complete solution for unilateral biportal endoscopic spine surgery (UBE): 4K endoscopic tower, Plasma and RF electrodes, dedicated instruments and an endoscopic drill.

A complete sterile set for biportal and monoportal spinal endoscopy: drapes, camera cover, fluid collection and the small instruments needed, in a single pack.

A modular anterior cervical fusion (ACDF) system that combines a TiPEEK interbody cage with an anterior plate: 4 plate types, rigid or variable fixation, 8 configurations.