EnSight Biportal
A complete solution for unilateral biportal endoscopic spine surgery (UBE): 4K endoscopic tower, Plasma and RF electrodes, dedicated instruments and an endoscopic drill.

NeuroMend does not bridge a gap: it wraps an injured nerve that is still in continuity after crushing or compression, or one that is partially severed. The membrane has shape memory: once applied, it curls around the nerve on its own with a 25% overlap, which lets it adapt to the nerve’s diameter and reduces the number of sutures needed.
The wrap is made of resorbable type I collagen, and its semipermeable wall lets small nutrients and neurotrophic factors through and acts as a barrier to scar-forming cells, according to the manufacturer. It comes in three sizes, for nerves of 2-4, 3-6 and 6-12 mm, each in 2.5 and 5.0 cm lengths.

| CNW4025, CNW4050 | Maximum inner diameter 4.0 mm; length 2.5 / 5.0 cm; nerve of 2-4 mm |
|---|---|
| CNW6025, CNW6050 | Maximum inner diameter 6.0 mm; length 2.5 / 5.0 cm; nerve of 3-6 mm |
| CNW12025, CNW12050 | Maximum inner diameter 12.0 mm; length 2.5 / 5.0 cm; nerve of 6-12 mm |
| Overlap | 25% recommended; at the maximum diameter the wrap edges meet end to end, which may require a running suture |
| Material | Type I collagen |
| Resorption | Through normal metabolic pathways in about 8 months (manufacturer’s preclinical data) |
| Shelf life | 3 years |
| Manufacturer | Collagen Matrix, Inc., Oakland, New Jersey, USA |
When the nerve is still in continuity: crushed, compressed or partially transected. NeuroMend wraps the injured nerve, whereas a conduit bridges two separate ends.
The membrane has shape memory and rolls itself around the nerve. The recommended overlap is 25%, which allows it to adapt to the nerve diameter and reduces the number of sutures.
Three, for nerves of 2-4, 3-6 and 6-12 mm, each in lengths of 2.5 and 5.0 cm.
Product
NeuroMend
Collagen Matrix
Fill in the form and we will get back to you shortly, usually within the same working day.

A complete solution for unilateral biportal endoscopic spine surgery (UBE): 4K endoscopic tower, Plasma and RF electrodes, dedicated instruments and an endoscopic drill.

A complete sterile set for biportal and monoportal spinal endoscopy: drapes, camera cover, fluid collection and the small instruments needed, in a single pack.

A modular anterior cervical fusion (ACDF) system that combines a TiPEEK interbody cage with an anterior plate: 4 plate types, rigid or variable fixation, 8 configurations.