title: "Aaxon DBS deep brain stimulation system | Ronda MedTech"
description: "Aaxon by SceneRay: a DBS system with a 30 g rechargeable neurostimulator, 4- or 8-contact leads, 3D visual programming and remote programming."
url: https://rondamedtech.ro/en/producatori/sceneray/aaxon-dbs/
lang: en
---

1.  [Home](https://rondamedtech.ro/en/)
2.  [Manufacturers](https://rondamedtech.ro/en/producatori/)
3.  [SceneRay](https://rondamedtech.ro/en/producatori/sceneray/)
4.  Aaxon DBS

[![SceneRay](https://rondamedtech.ro/logos/sceneray.png)](https://rondamedtech.ro/en/producatori/sceneray/)

# Aaxon DBS

A deep brain stimulation system with a 30 g rechargeable neurostimulator, 4- or 8-contact leads, 3D visual programming and remote programming.

[Neurosurgery](https://rondamedtech.ro/en/specialitati/neurochirurgie/)

![SceneRay Aaxon neurostimulators with leads connected](https://rondamedtech.ro/produse/sceneray/aaxon-neurostimulatoare.webp)

## Description

Aaxon is SceneRay’s deep brain stimulation (DBS) system for the treatment of movement disorders. The system comprises the rechargeable implantable neurostimulator, the stimulation leads, the extensions, the Touch-Loc lead fixation device and the programming apps for physician and patient.

The neurostimulator weighs 30 g, has a volume of 20 cm³ (48 × 50 × 10 mm) and a 200 mAh rechargeable battery. The patient charges it wirelessly, with a portable charger worn on the chest, from a distance of up to 2 cm: 5-10 minutes daily or 1-2 hours weekly. With typical parameters (3 V, 90 µs, 120 Hz), one charge lasts up to 48 days, according to the manufacturer.

Each lead can receive one or two independent stimulation sources, and the left and right hemispheres can be stimulated at different frequencies for asymmetric symptoms. Visual programming shows the deep brain nuclei, fibre tractography and the volume of tissue activated (VTA) in 3D, and the physician can also programme remotely, over video, at a time they choose.

![Components of the Touch-Loc lead fixation device](https://rondamedtech.ro/produse/sceneray/aaxon-touch-loc.webp)

## Indications

-   Movement disorders treated with deep brain stimulation
-   Parkinson’s disease, including refractory tremor, dyskinesia and freezing of gait

## Features

-   30 g, 20 cm³ rechargeable neurostimulator
-   Wireless charging from up to 2 cm, with a portable charger worn on the chest
-   Battery status shown in the programming app; alert 12 months before battery depletion
-   Software protection against excessive discharge and temperature control during charging
-   4- or 8-contact leads, 1.27 mm in diameter
-   One or two independent stimulation sources per lead; different frequencies for left and right
-   13 adjustable program sets: contact configuration, amplitude, frequency, pulse width
-   Touch-Loc: 1.5 mm thick lead fixation, curved to the skull, holding the lead at a force of 1 N
-   Visual programming: 3D deep brain nuclei, fibre tractography, VTA model
-   Remote programming over video, initiated by the physician
-   At least 25-year warranty, as stated by the manufacturer

## Technical specifications

Technical specifications: Aaxon DBS

Neurostimulator

SR1101-16 (8-contact system); SR1101 (4-contact system)

Dimensions, volume, weight

48 × 50 × 10 mm; 20 cm³; 30 g

Battery

Rechargeable, 200 mAh; wireless charging from max. 2 cm

8-contact leads

SR1212/SR1212-S: 1.5 mm contacts at 1.5 mm spacing, 22.5 mm active span; SR1202/SR1202-S: 1.5 mm contacts at 0.5 mm spacing, 15.5 mm active span

4-contact leads

SR1200: 0.5 mm spacing, 7.5 mm active span; SR1210: 1.5 mm, 10.5 mm; SR1211: 1.0 mm, 9.0 mm (1.5 mm contacts)

Lead diameter and length

1.27 mm; 400 mm

Extensions

SR1380 and SR1384, 610 mm (8-contact system); SR1341, 520 mm (4-contact system)

Lead fixation

Touch-Loc, 1.5 mm thick

Programs

13 adjustable sets

## Gallery

![Aaxon 8-contact lead](https://rondamedtech.ro/produse/sceneray/aaxon-electrod-8-contacte.webp)

![Wireless charger for the Aaxon neurostimulator](https://rondamedtech.ro/produse/sceneray/aaxon-incarcator.webp)

![Visual programming: deep brain nuclei in 3D](https://rondamedtech.ro/produse/sceneray/aaxon-programare-vizuala-3d.webp)

![Visual programming: volume of tissue activated (VTA) model](https://rondamedtech.ro/produse/sceneray/aaxon-model-vta.webp)

![Camera and device for remote programming](https://rondamedtech.ro/produse/sceneray/aaxon-programare-la-distanta.webp)

## Documents

-   [Aaxon DBS brochurePDF · en · 4,4 MB](https://rondamedtech.ro/documente/sceneray/aaxon-dbs-brosura.pdf)

## Frequently asked questions

### How is the neurostimulator charged?

Wirelessly, with a portable charger worn on the chest, from up to 2 cm away: 5-10 minutes daily or 1-2 hours weekly. With typical settings (3 V, 90 µs, 120 Hz), one charge lasts up to 48 days, according to the manufacturer.

### Can the two hemispheres be stimulated differently?

Yes. Each lead can receive one or two independent stimulation sources, and left and right can have different frequencies, for asymmetric symptoms. There are 13 adjustable programme sets.

### Which leads are available?

Leads with 4 or 8 contacts, 1.27 mm in diameter and 400 mm long. On the 8-contact leads, the active zone is 22.5 mm (SR1212) or 15.5 mm (SR1202); on the 4-contact leads, 7.5-10.5 mm.

### What are visual programming and remote programming?

Visual programming shows the deep brain nuclei, tractography and the volume of tissue activated (VTA) in 3D. The physician can also programme remotely, by video, at a time they set.

## Quote request

Product

Aaxon DBS

SceneRay

Fill in the form and we will get back to you shortly, usually within the same working day.

## Related products

Nexon Medical

### [EnSight Biportal](https://rondamedtech.ro/en/producatori/nexon-medical/ensight-biportal/)

A complete solution for unilateral biportal endoscopic spine surgery (UBE): 4K endoscopic tower, Plasma and RF electrodes, dedicated instruments and an endoscopic drill.

Product page

Nexon Medical

### [EnSight Drape Pack](https://rondamedtech.ro/en/producatori/nexon-medical/ensight-drape-pack/)

A complete sterile set for biportal and monoportal spinal endoscopy: drapes, camera cover, fluid collection and the small instruments needed, in a single pack.

Product page

Medacta

### [Mecta-C Stand Alone](https://rondamedtech.ro/en/producatori/medacta/mecta-c/)

A modular anterior cervical fusion (ACDF) system that combines a TiPEEK interbody cage with an anterior plate: 4 plate types, rigid or variable fixation, 8 configurations.

Product page

---
Quotes and information: https://rondamedtech.ro/en/contact/ · office@rondamedtech.ro · +40 727 221 112