---
title: "Immiseal absorbable synthetic dural sealant | Ronda MedTech"
description: "Immiseal by Medprin: a synthetic dural sealant that gels within seconds, helps prevent cerebrospinal fluid leakage and degrades in about 21 days."
url: https://rondamedtech.ro/en/producatori/medprin/immiseal/
lang: en
---

1.  [Home](https://rondamedtech.ro/en/)
2.  [Manufacturers](https://rondamedtech.ro/en/producatori/)
3.  [Medprin](https://rondamedtech.ro/en/producatori/medprin/)
4.  Immiseal

[![Medprin](https://rondamedtech.ro/logos/medprin.png)](https://rondamedtech.ro/en/producatori/medprin/)

# Immiseal

An absorbable synthetic dural sealant applied over the dural closure to prevent CSF leakage. It gels within seconds and degrades in about 21 days.

[Haemostasis and sealants](https://rondamedtech.ro/en/specialitati/hemostaza-si-sigilanti/) · [Neurosurgery](https://rondamedtech.ro/en/specialitati/neurochirurgie/)

![Immiseal dural sealant system: the dual syringe, with and without applicator](https://rondamedtech.ro/produse/medprin/immiseal-sistem.webp)

## Description

Immiseal is used as an adjunct to dural repair, after suturing or after onlay placement of autologous dura or a dural substitute. Over the closure line it forms a barrier that prevents cerebrospinal fluid leakage and limits dural adhesions.

The sealant is made of synthetic materials (PEG-SG and PEI). When they are mixed with water, electrophilic and nucleophilic reactions form a hydrogel within seconds. The raw material has a low molecular weight and the gel swells little, so it does not compress brain tissue: in the manufacturer’s tests, mass swelling was below 40% (by weight of absorbed water) and swelling in a single dimension was 10.7%.

The system comes ready to assemble. The two vials are connected to the syringes and shaken a few times to mix; then the vials are removed, the applicator is fitted and the sealant is ready to apply. It is stored below 30 °C and needs no thawing, so it is also available in emergencies.

![Immiseal dual syringe](https://rondamedtech.ro/produse/medprin/immiseal-seringa.webp)

## Indications

-   Adjunct to duraplasty: suturing or onlay of autologous dura or a dural substitute
-   Prevention of cerebrospinal fluid leakage after dural closure, in cranial and spinal surgery
-   Also used in tumour resection procedures

## Features

-   Absorbable synthetic hydrogel
-   Gels within seconds
-   Degrades in about 21 days (preclinical study)
-   Mass swelling below 40%; 10.7% in a single dimension
-   Watertight barrier over the dural suture line
-   Dual syringe with applicator, assembled in two steps
-   Stored below 30 °C, no thawing needed
-   5, 6, 8 and 10 ml volumes; 5, 10 and 15 cm applicator tips

## Technical specifications

Technical specifications: Immiseal

Composition

PEG-SG + PEI (synthetic hydrogel)

Volumes

5 ml, 6 ml, 8 ml, 10 ml

Applicator tip length

5 cm (A), 10 cm (C), 15 cm (E)

Configurations

DS4, DS2 and DS series, each in all volumes and tip lengths; the DS-050 … DS-100 series by volume only

Example codes

DS4A-050 = 5 ml, 5 cm tip; DS2E-100 = 10 ml, 15 cm tip; DS-080 = 8 ml

Degradation

About 21 days (preclinical study)

Preclinical pressure test

Watertight closure at 500 mmH₂O, 10 days after surgery (canine cranial surgery model)

Clinical trial

No CSF leakage at 7 ± 3 days after surgery in 65 of 65 cases (per-protocol set)

Storage

Below 30 °C

Packaging

1 unit per box

Country of manufacture

China

Manufacturer

Medprin (Medprin Regenerative Medical Technologies, Guangzhou); in Europe, Medprin Biotech GmbH, Frankfurt am Main

## Gallery

![Immiseal syringe and the two vials, before assembly](https://rondamedtech.ro/produse/medprin/immiseal-seringa-flacoane.webp)

## Documents

-   [Immiseal brochurePDF · en · 518 KB](https://rondamedtech.ro/documente/medprin/immiseal-brosura.pdf)
-   [Immiseal compared with other dural sealantsPDF · en · 128 KB](https://rondamedtech.ro/documente/medprin/immiseal-comparatie-sigilanti.pdf)

## Frequently asked questions

### When is Immiseal used?

As an adjunct to dural repair, after suturing or onlay application of autologous dura or a dural substitute, to prevent cerebrospinal fluid leakage. It is also used in tumour resection procedures.

### How quickly does the gel form and how long does it stay?

The hydrogel forms within seconds, through electrophile-nucleophile reactions on mixing with water, and degrades in about 21 days, according to the preclinical study.

### Does it compress brain tissue by swelling?

The manufacturer aimed for low swelling: in its tests, mass swelling was below 40%, by weight of absorbed water, and 10.7% in a single dimension.

### How is it prepared and stored?

The vials are connected to the syringes and shaken a few times, then the applicator is fitted. It is stored below 30 °C and needs no thawing. Volumes are 5, 6, 8 and 10 ml, with 5, 10 and 15 cm tips.

## Quote request

Product

Immiseal

Medprin

Fill in the form and we will get back to you shortly, usually within the same working day.

## Related products

Nexon Medical

### [EnSight Biportal](https://rondamedtech.ro/en/producatori/nexon-medical/ensight-biportal/)

A complete solution for unilateral biportal endoscopic spine surgery (UBE): 4K endoscopic tower, Plasma and RF electrodes, dedicated instruments and an endoscopic drill.

Product page

Nexon Medical

### [EnSight Drape Pack](https://rondamedtech.ro/en/producatori/nexon-medical/ensight-drape-pack/)

A complete sterile set for biportal and monoportal spinal endoscopy: drapes, camera cover, fluid collection and the small instruments needed, in a single pack.

Product page

Medacta

### [Mecta-C Stand Alone](https://rondamedtech.ro/en/producatori/medacta/mecta-c/)

A modular anterior cervical fusion (ACDF) system that combines a TiPEEK interbody cage with an anterior plate: 4 plate types, rigid or variable fixation, 8 configurations.

Product page

---
Quotes and information: https://rondamedtech.ro/en/contact/ · office@rondamedtech.ro · +40 727 221 112
