---
title: "NextAR Spine augmented-reality navigation | Ronda MedTech"
description: "NextAR Spine by Medacta: spine surgery navigation with guidance shown in smart glasses, single-use sensors and planning on CT or during surgery."
url: https://rondamedtech.ro/en/producatori/medacta/nextar/
lang: en
---

1.  [Home](https://rondamedtech.ro/en/)
2.  [Manufacturers](https://rondamedtech.ro/en/producatori/)
3.  [Medacta](https://rondamedtech.ro/en/producatori/medacta/)
4.  NextAR Spine

[![Medacta](https://rondamedtech.ro/logos/medacta.svg)](https://rondamedtech.ro/en/producatori/medacta/)

# NextAR Spine

Augmented-reality navigation for spine surgery: guidance appears directly in the surgeon’s field of view through smart glasses, with compact sensors mounted close to the operated levels.

[Neurosurgery](https://rondamedtech.ro/en/specialitati/neurochirurgie/) · [Orthopaedics and traumatology](https://rondamedtech.ro/en/specialitati/ortopedie/)

![NextAR glasses, with the guidance shown in the field of view](https://rondamedtech.ro/produse/medacta/nextar-ochelari.webp)

## Description

NextAR Spine is Medacta’s augmented-reality application for spine surgery. The system measures the position of the instruments relative to the patient’s anatomy in real time and shows the information in the NextAR glasses, superimposed on the operative field, so the surgeon does not have to look away at a monitor.

Tracking uses compact, single-use active sensors mounted close to the treated levels, with no reflective markers and no bulky external camera in the room. The NextAR camera communicates with the control unit over Bluetooth, and the battery-powered NextAR target carries LEDs in a known configuration that the camera tracks.

The surgeon chooses between two workflows. In 3D-3D, implant placement is planned in advance on a 3D model built from a low-dose CT scan. In 3D DIRECT, the desired trajectories are saved intraoperatively with a single click. The same software and hardware cover open, mini-open and percutaneous approaches, and Medacta also uses the NextAR platform for the knee, hip and shoulder.

![Surgeon working with NextAR Spine, with the guidance superimposed on the operative field](https://rondamedtech.ro/produse/medacta/nextar-sala-de-operatie.webp)

## Indications

-   Spine surgery: degenerative conditions and deformity
-   Spinal trauma and tumours
-   Open, mini-open and percutaneous approaches

## Features

-   Augmented-reality guidance shown in the NextAR glasses over the operative field
-   Lightweight wireless glasses with an integrated camera, USB connection and an option for prescription lenses
-   NextAR TS tracking system: compact, single-use active sensors mounted close to the treated levels
-   No reflective markers and no external detection platform
-   Preoperative 3D-3D planning on low-dose CT or intraoperative 3D DIRECT planning
-   Integrated with the MySpine planning tools of the Medacta MySolutions ecosystem
-   Navigated instruments compatible with the Medacta spine system instruments
-   NextAR Rod Optimizer: intraoperative rod selection from a set of pre-bent rods, without manual bending

## Technical specifications

Technical specifications: NextAR Spine

Components

NextAR glasses, NextAR TS tracking system (camera and target), control unit, software

Camera to control unit link

Bluetooth

Sensors

Active, single-use; battery-powered LED target

Workflows

3D-3D (planned on CT) and 3D DIRECT (intraoperative)

Planning imaging

Low-dose CT (3D-3D workflow)

Approach

Open, mini-open, percutaneous

Platform

NextAR, shared across spine, knee, hip and shoulder

## Gallery

![NextAR navigated instrument with camera and target mounted on the spine](https://rondamedtech.ro/produse/medacta/nextar-instrument-urmarit.webp)

![NextAR Spine screen with the screw trajectory on CT images](https://rondamedtech.ro/produse/medacta/nextar-planificare-ecran.webp)

![Augmented-reality view: angle, depth and trajectory on the 3D model of the vertebra](https://rondamedtech.ro/produse/medacta/nextar-ghidare-ar.webp)

## Documents

-   [NextAR brochurePDF · en · 1,9 MB](https://rondamedtech.ro/documente/medacta/nextar-spine-brosura.pdf)

## Frequently asked questions

### Where does the surgeon see the navigation data?

In the NextAR glasses. The angle, depth and trajectory of the instrument are superimposed on the operative field, so the surgeon does not look away at a monitor during the procedure.

### Does it need a large navigation camera in the room?

No. Tracking uses compact, single-use active sensors mounted close to the operated levels: a small camera and a battery-powered LED target. The camera communicates with the control unit over Bluetooth, and no reflective markers are needed.

### Which workflows does NextAR Spine offer?

Two. In 3D-3D, implant placement is planned before surgery on a 3D model built from a low-dose CT scan. In 3D DIRECT, the surgeon saves the desired trajectories during surgery with a single click. Both cover open, mini-open and percutaneous approaches.

### How does NextAR Spine relate to MySpine and pre-bent rods?

NextAR Spine is integrated with the MySpine planning tools of Medacta’s MySolutions ecosystem. The NextAR Rod Optimizer helps choose the right rod during surgery from a set of pre-bent rods, without manual bending.

## Quote request

Product

NextAR Spine

Medacta

Fill in the form and we will get back to you shortly, usually within the same working day.

## Related products

Nexon Medical

### [EnSight Biportal](https://rondamedtech.ro/en/producatori/nexon-medical/ensight-biportal/)

A complete solution for unilateral biportal endoscopic spine surgery (UBE): 4K endoscopic tower, Plasma and RF electrodes, dedicated instruments and an endoscopic drill.

Product page

Nexon Medical

### [EnSight Drape Pack](https://rondamedtech.ro/en/producatori/nexon-medical/ensight-drape-pack/)

A complete sterile set for biportal and monoportal spinal endoscopy: drapes, camera cover, fluid collection and the small instruments needed, in a single pack.

Product page

Medacta

### [Mecta-C Stand Alone](https://rondamedtech.ro/en/producatori/medacta/mecta-c/)

A modular anterior cervical fusion (ACDF) system that combines a TiPEEK interbody cage with an anterior plate: 4 plate types, rigid or variable fixation, 8 configurations.

Product page

---
Quotes and information: https://rondamedtech.ro/en/contact/ · office@rondamedtech.ro · +40 727 221 112
