title: "Mecta-C Stand Alone ACDF cage with plate | Ronda MedTech"
description: "Mecta-C Stand Alone by Medacta: TiPEEK cage with an anterior plate for cervical fusion (ACDF) from C2 to T1, with rigid or variable fixation and 4 plates."
url: https://rondamedtech.ro/en/producatori/medacta/mecta-c/
lang: en
---

1.  [Home](https://rondamedtech.ro/en/)
2.  [Manufacturers](https://rondamedtech.ro/en/producatori/)
3.  [Medacta](https://rondamedtech.ro/en/producatori/medacta/)
4.  Mecta-C Stand Alone

[![Medacta](https://rondamedtech.ro/logos/medacta.svg)](https://rondamedtech.ro/en/producatori/medacta/)

# Mecta-C Stand Alone

A modular anterior cervical fusion (ACDF) system that combines a TiPEEK interbody cage with an anterior plate: 4 plate types, rigid or variable fixation, 8 configurations.

[Neurosurgery](https://rondamedtech.ro/en/specialitati/neurochirurgie/) · [Orthopaedics and traumatology](https://rondamedtech.ro/en/specialitati/ortopedie/)

![Mecta-C Stand Alone with a rigid fixation plate (purple)](https://rondamedtech.ro/produse/medacta/mecta-c-fixare-rigida.webp)

## Description

Mecta-C Stand Alone brings together in one implant the benefits of an anterior cervical plate and a radiolucent interbody cage. The cage comes in three footprints and eight heights, with a fixed lordosis of 7°. During surgery the surgeon chooses one of four plates, Flush, Hybrid, Trio or Quattro, and snaps it onto the cage with the dedicated instruments.

Each plate comes in two versions. Rigid fixation (purple plate) uses locking screws in a threaded plate, with an integrated anti-backout system. Variable fixation (blue plate) uses lag screws in an unthreaded plate that allows micro-motion and load distribution to the bone; the screws are secured with a central anti-backout screw supplied with the plate.

The cage is made of PEEK plasma-sprayed with a micrometric titanium layer (TiPEEK). Titanium markers allow the position to be checked on X-ray, and the wide central window is filled with bone graft. The system is contraindicated in spinal fractures, tumours and infections and in severe osteoporosis.

![Mecta-C Stand Alone implants on a cervical spine model](https://rondamedtech.ro/produse/medacta/mecta-c-coloana-cervicala.webp)

## Indications

-   Anterior cervical interbody fusion in skeletally mature patients with cervical disc degeneration and/or cervical instability confirmed by imaging
-   Radiculopathy, myelopathy and/or pain at contiguous levels from C2 to T1
-   Used with autologous and/or allogeneic bone graft

## Features

-   One cage, two fixation types, four plates: 8 configurations
-   Flush: zero-profile construct
-   Hybrid: for C7-T1 or, rotated by 180°, for C2-C3, to avoid the neighbouring anatomical structures
-   Trio: three screws
-   Quattro: four screws, two convergent and two divergent, to limit interference with the adjacent level in multilevel fixation
-   Radiolucent TiPEEK cage with titanium markers and pyramid-shaped teeth on the cranial and caudal surfaces
-   Self-drilling and self-tapping screws for both fixation types
-   Implants supplied sterile
-   Colour-coded instruments, with awl, drill, tap and screwdriver angled at 25° for difficult anatomy

## Technical specifications

Technical specifications: Mecta-C Stand Alone

Cage footprint (W × D)

15 × 13, 16 × 14 and 18 × 15 mm

Cage height

5-12 mm, in 1 mm steps

Lordosis

7°

Cage material

Titanium-coated PEEK (TiPEEK), titanium markers

Plates

Flush and Hybrid: h6-h12; Trio and Quattro: h5-h12

Rigid fixation

Threaded plate (purple), locking screws

Variable fixation

Unthreaded plate (blue), lag screws, central anti-backout screw

Screw diameter

3.8 mm (primary), 4.2 mm (revision)

Self-drilling screws

12-20 mm, in 2 mm steps

Self-tapping screws

12-22 mm, in 2 mm steps

Levels

C2-T1

Marking

CE 0476

## Gallery

![Flush plate, in the rigid (purple) and variable (blue) fixation versions](https://rondamedtech.ro/produse/medacta/mecta-c-placa-flush.webp)

![Hybrid plate, in the rigid and variable fixation versions](https://rondamedtech.ro/produse/medacta/mecta-c-placa-hybrid.webp)

![Trio plate, with three screws, in the rigid and variable fixation versions](https://rondamedtech.ro/produse/medacta/mecta-c-placa-trio.webp)

![Quattro plate, with four screws, in the rigid and variable fixation versions](https://rondamedtech.ro/produse/medacta/mecta-c-placa-quattro.webp)

![Mecta-C Stand Alone with a variable fixation plate (blue) and central anti-backout screw](https://rondamedtech.ro/produse/medacta/mecta-c-fixare-variabila.webp)

![TiPEEK cage: 15 × 13, 16 × 14 and 18 × 15 mm footprints, 5-12 mm heights](https://rondamedtech.ro/produse/medacta/mecta-c-dimensiuni.webp)

## Documents

-   [Mecta-C Stand Alone brochurePDF · en · 972 KB](https://rondamedtech.ro/documente/medacta/mecta-c-stand-alone-brosura.pdf)
-   [Mecta-C Stand Alone surgical techniquePDF · en · 2,7 MB](https://rondamedtech.ro/documente/medacta/mecta-c-stand-alone-tehnica-chirurgicala.pdf)

## Frequently asked questions

### What does "stand alone" mean for Mecta-C?

The interbody cage and the anterior plate form a single implant. The plate snaps onto the cage, and the screws pass through the plate into the vertebral bodies, so one construct does the job of both the cage and the cervical plate.

### What is the difference between rigid and variable fixation?

Rigid fixation uses a threaded purple plate with locking screws and an integrated anti-backout system. Variable fixation uses an unthreaded blue plate with lag screws, which allows micro-motion and load sharing with the bone; the screws are secured by a central anti-backout screw. Both versions exist for all four plates.

### Which plate is used at C7-T1, at C2-C3 or over several levels?

The Hybrid plate is designed for C7-T1 and, rotated by 180°, is used at C2-C3 to avoid the neighbouring anatomical structures. For multilevel fixation, the Quattro plate has two convergent and two divergent screws to limit interference with the adjacent level. Flush gives a zero-profile construct and Trio has three screws.

### What sizes and material does the cage come in?

The cage comes in three footprints, 15 × 13, 16 × 14 and 18 × 15 mm, and in heights of 5-12 mm in 1 mm steps, with 7° of lordosis. It is made of PEEK with a micrometric titanium coating (TiPEEK), has titanium markers for radiographic control and a central window for bone graft.

## Quote request

Product

Mecta-C Stand Alone

Medacta

Fill in the form and we will get back to you shortly, usually within the same working day.

## Related products

Nexon Medical

### [EnSight Biportal](https://rondamedtech.ro/en/producatori/nexon-medical/ensight-biportal/)

A complete solution for unilateral biportal endoscopic spine surgery (UBE): 4K endoscopic tower, Plasma and RF electrodes, dedicated instruments and an endoscopic drill.

Product page

Nexon Medical

### [EnSight Drape Pack](https://rondamedtech.ro/en/producatori/nexon-medical/ensight-drape-pack/)

A complete sterile set for biportal and monoportal spinal endoscopy: drapes, camera cover, fluid collection and the small instruments needed, in a single pack.

Product page

Medacta

### [NextAR Spine](https://rondamedtech.ro/en/producatori/medacta/nextar/)

Augmented-reality navigation for spine surgery: guidance appears directly in the surgeon’s field of view through smart glasses, with compact sensors mounted close to the operated levels.

Product page

---
Quotes and information: https://rondamedtech.ro/en/contact/ · office@rondamedtech.ro · +40 727 221 112