---
title: "IntraSPINE dynamic interlaminar implant (L1-S1)"
description: "IntraSPINE by Cousin Surgery: a dynamic silicone interlaminar implant for L1-S1 that maintains foraminal height; mini-invasive or midline approach."
url: https://rondamedtech.ro/en/producatori/cousin-surgery/intraspine/
lang: en
---

1.  [Home](https://rondamedtech.ro/en/)
2.  [Manufacturers](https://rondamedtech.ro/en/producatori/)
3.  [Cousin Surgery](https://rondamedtech.ro/en/producatori/cousin-surgery/)
4.  IntraSPINE

[![Cousin Surgery](https://rondamedtech.ro/logos/cousin-surgery.svg)](https://rondamedtech.ro/en/producatori/cousin-surgery/)

# IntraSPINE

A dynamic interlaminar implant for the lumbar and sacral spine (L1-S1) that preserves motion and keeps the foraminal space open; mini-invasive unilateral or midline bilateral approach.

[Neurosurgery](https://rondamedtech.ro/en/specialitati/neurochirurgie/)

![IntraSPINE interlaminar implant](https://rondamedtech.ro/produse/cousin-surgery/intraspine-implant.webp)

## Description

IntraSPINE is a dynamic stabilisation system that respects the physiological motion of the spine. The implant rests on the laminae, closer to the instantaneous axis of rotation than conventional interspinous devices, which allows decompression and maintenance of lordosis.

The implant is made of silicone covered with polyester. The rigid anterior nose maintains foraminal height, the soft posterior tunnel absorbs shocks without limiting motion, the anterior wings prevent migration, and a silicone film reduces adhesions.

It is implanted either through a mini-invasive unilateral approach, with the implant alone, or through a midline bilateral approach, with the implant and the polyester artificial ligament. The instrument set includes the distraction forceps, trial devices for the 5 sizes, the implant holder, the impactor and the ligament tightener.

![IntraSPINE: silicone implant covered with polyester, with a silicone film](https://rondamedtech.ro/produse/cousin-surgery/intraspine-film-silicon.webp)

## Indications

-   Arthropathic facet syndrome
-   Foraminal stenosis
-   Degenerative discopathy
-   Intervertebral ligament insufficiency

## Features

-   Use from L1 to S1
-   Laminar support, close to the instantaneous axis of rotation
-   Rigid anterior nose for anterior distraction and maintenance of foraminal height
-   Soft posterior tunnel acting as a shock absorber
-   Anterior anti-migration wings
-   Anti-adhesion silicone film
-   Optional polyester artificial ligament
-   Mini-invasive unilateral or midline bilateral approach

## Technical specifications

Technical specifications: IntraSPINE

Sizes (nose height)

8, 10, 12, 14 and 16 mm

Implant references

5 sizes: INTRACAL08, INTRACAL10, INTRACAL12, INTRACAL14, INTRACAL16

Materials

Silicone covered with polyester; polyester ligament with a titanium buckle

Levels

L1-S1

Classification

Implant Class IIb; instruments Class I; trial devices Class IIa

Manufacturer

Cousin Biotech S.A.S., France

## Gallery

![IntraSPINE with the polyester artificial ligament and titanium buckle](https://rondamedtech.ro/produse/cousin-surgery/intraspine-ligament.webp)

![Illustration: inserting the IntraSPINE implant into the interlaminar space](https://rondamedtech.ro/produse/cousin-surgery/intraspine-insertie.webp)

![Illustration: final position of IntraSPINE with ligament, posterior view](https://rondamedtech.ro/produse/cousin-surgery/intraspine-pozitie-finala.webp)

![IntraSPINE trial devices in the 5 sizes and their assembly on the handle](https://rondamedtech.ro/produse/cousin-surgery/intraspine-proba.webp)

## Clinical studies and publications

1.  Surgical outcomes of patients with degenerative lumbar disc disease post-IntraSPINE device fixation: three-year prospective studyCo-Minh D, Vajeu C, Montron L, Aylott CEW et al. · _International Journal of Clinical Case Reports and Reviews 8(1)_, 2021[DOI 10.31579/2690-4861/130](https://doi.org/10.31579/2690-4861/130)
2.  The likelihood of reaching substantial clinical benefit after an interlaminar dynamic spacer for chronic low back pain: a clinical and radiologic analysis of a prospective cohortBae J, Lee SM, Lee SH, Shin SH, Kim HJ, Kim KH · _World Neurosurgery 101:589-598_, 2017[DOI 10.1016/j.wneu.2017.02.083](https://doi.org/10.1016/j.wneu.2017.02.083)
3.  Microdiscectomy with and without insertion of interspinous device for herniated disc at the L5-S1 levelGalarza M, Gazzeri R, De la Rosa P, Martínez-Lage JF · _Journal of Clinical Neuroscience 21(11):1934-1939_, 2014[DOI 10.1016/j.jocn.2014.02.029](https://doi.org/10.1016/j.jocn.2014.02.029)
4.  Lumbar herniated disc treated by microdiscectomy alone or microdiscectomy plus an interlaminar shock absorbing device: retrospective study with minimum 3-years follow-upCorriero OV, Morichi R, Vagaggini A, Paoli L, Guizzardi G · _Journal of Spine 3(2)_, 2013[DOI 10.4172/2165-7939.1000159](https://doi.org/10.4172/2165-7939.1000159)
5.  Interlaminar lumbar device implantation in treatment of Baastrup disease (kissing spine)Mostofi K, Gharaei Moghadam B, Peyravi M · _Journal of Craniovertebral Junction and Spine 9(2):83_, 2018[DOI 10.4103/jcvjs.JCVJS\_139\_17](https://doi.org/10.4103/jcvjs.JCVJS_139_17)

## Documents

-   [IntraSPINE surgical techniquePDF · en · 900 KB](https://rondamedtech.ro/documente/cousin-surgery/intraspine-tehnica-chirurgicala.pdf)
-   [BDyn and IntraSPINE clinical book: study abstractsPDF · en · 685 KB](https://rondamedtech.ro/documente/cousin-surgery/bdyn-intraspine-studii-clinice.pdf)

## Frequently asked questions

### How does IntraSPINE differ from an interspinous implant?

IntraSPINE rests on the laminae rather than between the spinous processes, so it sits closer to the segment’s instantaneous axis of rotation. This position allows decompression and maintenance of lordosis without blocking physiological motion.

### What sizes are there and how is the size chosen?

Five sizes, by nose height: 8, 10, 12, 14 and 16 mm. The size is chosen during surgery with the trial devices, mounted on a handle, after distraction with the dedicated forceps.

### When is the artificial ligament used?

In the midline bilateral approach, the implant is secured with the polyester ligament and titanium buckle. In the mini-invasive unilateral approach, the implant is used on its own.

### What is the implant made of?

Silicone covered with polyester. The anterior nose is rigid and maintains foraminal height, the posterior tunnel is soft and absorbs shocks, the anterior wings prevent migration, and a silicone film reduces adhesions.

## Quote request

Product

IntraSPINE

Cousin Surgery

Fill in the form and we will get back to you shortly, usually within the same working day.

## Related products

Nexon Medical

### [EnSight Biportal](https://rondamedtech.ro/en/producatori/nexon-medical/ensight-biportal/)

A complete solution for unilateral biportal endoscopic spine surgery (UBE): 4K endoscopic tower, Plasma and RF electrodes, dedicated instruments and an endoscopic drill.

Product page

Nexon Medical

### [EnSight Drape Pack](https://rondamedtech.ro/en/producatori/nexon-medical/ensight-drape-pack/)

A complete sterile set for biportal and monoportal spinal endoscopy: drapes, camera cover, fluid collection and the small instruments needed, in a single pack.

Product page

Medacta

### [Mecta-C Stand Alone](https://rondamedtech.ro/en/producatori/medacta/mecta-c/)

A modular anterior cervical fusion (ACDF) system that combines a TiPEEK interbody cage with an anterior plate: 4 plate types, rigid or variable fixation, 8 configurations.

Product page

---
Quotes and information: https://rondamedtech.ro/en/contact/ · office@rondamedtech.ro · +40 727 221 112
